GE Security
g
LOCATIONS 207-211 - RESERVED
LOCATION 212 – PROGRAMMING THE LCD KEYPAD ADDRESS (1 segment, numerical data)
When using the XSIA dialler format, the system requires at least 1 LCD keypad. The
panel will get the zone descriptions from the first language from that LCD keypad which
has the address defined in location 212. If your system has an LCD keypad it is
recommended that it will be placed in location 1 keypad 1. This will allow location 212 to
be left at the factory default. If the LCD keypad is selected as something other than
partition 1 / keypad 1, program the appropriate address in location 212. Select the
address from the location chart.
Keypad Part 1 Part 2
1 192 193
2 200 201
3 208 209
4 216 217
5 224 225
6 232 233
7 240 241
8 248 249
LOCATION 213 – PROGRAMMING THE COUNTRY CODE (1 segment, numerical data)
The NX-6 has the ability to set different “country codes”. Each country code has specific
default settings. Before start programming the NX-6, it is important to select the country
code that is required (see table below). Once the country code has been selected, it will
remain set, even after an installer reset. When changing the country code during
programming, all existing programming will be cleared to the defaults for that country.
Code Country
0 No country (default)
1 Holland
2 Belgium / Poland
3 Sweden
4 Italy
5 Spain / Portugal
6 Greece
7 South Africa
50 US
NX-6-EUR Installation manual Page 78 23/12/04