GE Security
g
NOTE:
ANY MASTER ARM/DISARM CODE CAN ADD OR CHANGE A USER CODE IF THE
MASTER CODE HAS ACCESS TO THE SAME PARTITIONS AS THE CODE BEING
ADDED/CHANGED. CONSEQUENTLY, WHEN PROGRAMMING THE USER CODES
FOR A PARTITIONED SYSTEM, LEAVE AT LEAST ONE CODE WITH ACCESS TO
ALL PARTITIONS. UNLESS YOU DO THIS, YOU WILL NOT BE ABLE TO ADD NEW
USERS. (THE CODE CAN BE THE “GO TO PROGRAM CODE”, IF ENABLED IN
LOCATION 43). IF YOU WANT TO LET THE END USER ADD NEW CODES, YOU
MUST REMOVE THE PARTITION AUTHORITY FROM ALL BLANK CODES.
[*]-[CHIME] ACTIVATING WALKTEST:
1. Enter [*]-[CHIME].
2. Enter [Master code].
3. Activate all sensors to test. Each activation of a sensor is confirmed with a “ding
dong” sound with a corresponding flashing zone-indicator.
4. Enter [Master code]. Herewith the walktest-mode is left.
Remark: Walktest mode is not possible if any partition is armed or if the
communicator is active.
Additional keypad functions are described in the appropriate user manual
NX-6-EUR Installation manual Page 17 23/12/04