[*]-[5] CHANGING USER CODES
1. Enter [*]-[5]-[master code]- the “Ready” LED will flash.
2. Enter the 2 digit user number (always 2 digits, such as “03” for user 3)- the “Ready”
LED will illuminate steadily.
3. Enter the new user code designated for the person in question - the “Ready” LED
will flash, indicating that the code has been accepted. If the code is rejected, the
sounder will beep 3 times.
4. If another user code needs to be programmed, return to step 2.
5. Press [#] while the “Ready” LED is flashing in order to exit the user code
programming mode.
6. Pressing four times (for 4-digit code) can erase a user code or six times (for 6-digit
code) the “Cancel” key.
[*]-[6] ASSIGNING AUTHORITY LEVEL
1. Enter [*]-[6]-[master code]- the “Ready” LED will flash.
2. Enter [2 digit user number] (always 2 digits, such as 03 for user 3)- the “Ready” LED
will illuminate steadily and the “Instant” LED will flash. Refer to the chart below for
the description of each LED. Turn on the LED for the features that you want.
LED ATTRIBUTES IF LED 8 IS OFF LED ATTRIBUTES IF LED 8 IS ON
1 Reserved 1 Activate output 1
2 Arm only 2 Activate output 2
3 Arm only after closing window 3 Activate output 3
4
Master arm/disarm (can program
other codes)
4 Activate output 4
5 Arm/disarm code 5 Arm/disarm code
6
Allowed to bypass zones (see
location 23)
6
Allowed to bypass zones (see
location 23)
7 Code will send open / close reports 7 Code will send open / close reports
8
If this LED is on, LED’s 1-7 will use
the chart too the right
8
If this LED is off, LED’s 1-7 will use
the chart on the left
1. Enter [*]: The “Instant” LED will illuminate steadily.
This moves you to the ‘partition enable’. (This tells the system which partition this
user can arm/disarm.) LED’s 1-8 will light up for each partition that the user is
authorised to arm/disarm. To change any of these numbers, press 1-8 to permit or
deny access to the user. (Example: If LED 2 is lit, then the user has been assigned
access to that partition. By pressing the [2] key, the LED will go out, indicating the
user has been denied access to that partition.)
2. Enter [*]:
This brings you back to step 2 above. At this point, you may enter another user
number to which you can assign attributes. You may continue this procedure until
you have assigned authority levels to all user numbers; otherwise, you may press
the [#] key to exit the assigning authority level program.