GE Security
g
ALPHANUMERIC CHARACTER TABEL
1 A 20 T 39 ä 58 n 77 #
2 B 21 U 40 ä 59 o 78 $
3 C 22 V 41 b 60 ô 79 &
4 D 23 W 42 c 61 ö 80 '
5 E 24 X 43 ç 62 p 81 (
6 F 25 Y 44 d 63 q 82 )
7 G 26 Z 45 e 64 r 83 *
8 H 27 0 46 é 65 s 84 +
9 I 28 1 47 è 66 t 85 ,
10 J 29 2 48 ê 67 u 86 -
11 K 30 3 49 f 68 û 87 .
12 L 31 4 50 g 69 ü 88 /
13 M 32 5 51 h 70 v 89 :
14 N 33 6 52 i 71 w 90 ;
15 O 34 7 53 î 72 x 91 <
16 P 35 8 54 j 73 y 92 =
17 Q 36 9 55 k 74 z 93 >
18 R 37 a 56 l 75 ! 94
19 S 38 à 57 m 76 ” 95 °
EXITING THE PROGRAM MODE
When you have made all the desired changes in programming, it is time to exit the
program mode. Press the [Exit] key to exit this programming level, and go to the “Select a
Module To Program” level. If no additional modules are to be programmed, press the
[Exit] key again to exit the program mode. If there is a module to be programmed, you
can select it by entering its address, followed by the [#] key (see “Selecting the Module To
Program” above). The procedure for programming these devices is the same as for the
control panel, except that the locations will be for the module selected.
Note: the timeout for the program mode is 15 minutes.
LOADING FACTORY DEFAULTS
To load the factory defaults, enter the program mode using the above procedure, then
type [9]-[1]-[0]-[#]. The keypad will beep 3 times to show that loading is in progress. The
loading takes about 6 seconds.
ENROLLING MODULES AND KEYPADS
For supervision purposes, the presence of all keypads, zone expanders, wireless
receivers, and any other modules connected to the data terminal can automatically be
found and stored in the NX-6’s memory. This allows the control panel to supervise these
modules. Note: All modules should be connected and set to unique addresses before
modules are enrolled. To enroll the modules, enter the program mode of the NX-6 control
panel as described above. If necessary, go on to program the rest of the control panel
and devices. When you exit from program mode, the control panel will automatically
enroll the devices. The enrolling process takes about 12 seconds, during this time the
“Service Screen” will be displayed. If a module has been enrolled but it is not detected by
the control, the “Service Screen” will be displayed.
NX-6-EUR Installation manual Page 32 23/12/04