GE Security
g
LOCATION 43 - GO TO PROGRAM CODE PARTITION AND AUTHORIZATION (2 segments, feature
selection data)
The “Go To Program Code” can be used as a standard arm/disarm code. When using the
code to arm or disarm, the user ID is 255. (It is not possible to change this code in the run
mode).
Segment 1
1 = Reserved
2 = On: enables “Go To Program Code” as an arm only code
3 = On: enables “Go To Program Code” as an arm only, after closing
4 =
On: enables “Go To Program Code” as a master arm/disarm code
(can change user codes)
5 = On: enables “Go To Program Code” as an arm/disarm code
6 = On: enables “Go To Program Code” to bypass zones
7 = On: enables “Go To Program Code” opening and closing reports
8 = Reserved
Segment 2
1 = On: enables the “Go To Program Code” for partition 1
2 = On: enables the “Go To Program Code” for partition 2
3-8 Reserved
) LOCATION 44 - DURESS CODE (6 segments, numerical data)
Location 43 contains the “Duress” code. This Location contains either 4 or 6 digits. If the
6-digit code option is enabled in location 41, THIS CODE MUST CONTAIN SIX (6)
DIGITS. If the 6-digit option is not enabled in location 41, the last 2 digits will be ignored.
If the duress code is programmed, it will work for all partitions.